logo
Para casa > produtos > sensor da qualidade de água >
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants

Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants

Reagent Type Residual Chlorine Sensor

0-10 mg/L Measuring Range Chlorine Analyzer

100-240 V DC Power Supply Water Quality Sensor

Marca:

Yokogawa

Número do modelo:

RC800D

Contacte-nos
Solicite um orçamento
Detalhes do produto
Objeto medido:
Cloro livre ou cloro residual (cloro total) em água
Sistema de medição:
Método amperométrico (método polarográfico) usando eletrodo rotativo
Faixa de medição:
0-10 mg/l
Fonte de energia:
100 a 240 V DC, 50/60 Hz
Destacar:

Reagent Type Residual Chlorine Sensor

,

0-10 mg/L Measuring Range Chlorine Analyzer

,

100-240 V DC Power Supply Water Quality Sensor

Termos de pagamento e envio
Quantidade de ordem mínima
1pcs
Detalhes da embalagem
Cada unidade possui caixa individual e todas as caixas são embaladas em pacotes padrão ou solicitaçõ
Tempo de entrega
5-8 dias de trabalho
Termos de pagamento
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Habilidade da fonte
1000 peças/peças por semana negociável
Descrição do produto
Reagent Type Residual Chlorine Sensor Unit RC800D
Reliable Chlorine Measurements in Water Treatment Plants Since 1959

No.1 Process analyzer supplier to Japanese market*

"Reliable Chlorine monitoring and minimize Chlorine injection"

"Continuous automatic cleaning and achieved less maintenance time"

"Maintenance remotely and reduce maintenance time"

Many of our customers face these challenges - Yokogawa Chlorine Analyzers resolve them.

The RC800D residual chlorine analyzer employs a polarographic system that uses rotating platinum electrodes to provide a continuous online measurement of residual chlorine concentration. It is possible to separate residual chlorine (free chlorine + combined-chlorine) from free chlorine for measurements by appropriate use of reagents.

The RC800D is suitable for various water condition measurements and gives you a stable and high-quality measurement thanks to the rotation electrodes and superior reagent pump.

The RC800D is intended for water distribution measurements at pumping stations, water delivery points, schools, and public facilities.

*Based on a Yokogawa survey in 2019

Key Features
  • Amperometric measurement of free chlorine or total chlorine (polarographic method)
  • Measure Free chlorine or residual chlorine (total chlorine) continuously in water
  • Unique rotation electrode method keeps sensor clean and reduces maintenance cycle
  • Superior reagent pump realizes stable measurement regardless of sample conditions
  • Easy maintenance structure, modularized motor unit, and diagnostics functions strongly support regular maintenance
  • Remote wash and calibration functions are available
  • RC800D is equipped with Manual calibration and Auto Calibration, 2 points correction, Basic (reference) sensitivity calibration, and circuit open Zero calibration
  • Remote range switching is available
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants 0
RC800D Left Side View
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants 1
RC800D Easy to Use Touch Screen Display
Structure
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants 2
TC8000D Structure Diagram
Applications
Each process at treatment plant: from reservoir to treated water, distribution system
  • Water Purification Treatment
  • Stabilization
  • Flocculation
  • Settling Basins
  • Chlorination
  • Clean water reservoir
  • Distributing pump
  • Distribution tank & Piping
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants 3
Use Case Diagram
Specifications
Measured Object Free chlorine or residual chlorine (total chlorine) in water
Measuring System Amperometric method (Polarographic method) using rotating electrode
Measuring Range 0-10 mg/L
Sample Conditions Temperature: 0 to 50°C (Temperature compensation is effective within 0 to 40°C)
pH: 3 to 9
Flow Rate: 1 to 4 L/min, for pure water or municipal water application.
5 to 10 L/min, for raw water or sea water application.
10 to 20 L/min, for secondary sewage treatment application.
Pressure 20 to 500 kPa
Power Supply 100 to 240 V DC, 50/60 Hz
Digital Communication Modbus TCP/IP, Modbus RTU
Installation Indoor (Outdoor use requires protection against rain. Direct sunlight must be avoided.)
Performance
Linearity ±3% of reading or ±0.03 mg/L whichever is greater
Repeatability ±1% of reading or ±0.01 mg/L whichever is greater

Envie a sua consulta directamente para nós

Política de Privacidade China Boa Qualidade sensor da qualidade de água Fornecedor. Copyright © 2018-2025 Xi'an Kacise Optronics Co.,Ltd. Todos os direitos reservados.